Make sure that the Protective Earth of the power supply is connected to the Earth connection of the MPC-STD.
Connect the PC end of Programming cable (Cable 2) to the serial port on the computer. Connect the MPC-COM2 end of Cable 2 to the MPC-STD port labeled COM2 / PLC2. Insert the other end of the 6ft Ethernet cable into the connector labeled PC.
Bahamas Immigration Card Pdf Reader here.
And understand How to use modscan32 - Duration: 39:56. It is recommended to use Micrologic software like RCU, RDU, or RSU rather than the third party software to work with Micrologic P or H type relay.Modscan 32 Project MGL Esteban m. When opening communication of RCU, it will enable remote access automatically for Micrologic P. This value represents the phase A current in amps.ĥ. For example: Using Modscan32, input Address = 1016 (register number) Length = 1 select your Device ID and holding register, you will receive 41016: =. Those values of currents, power factors (PF's), voltages, and the different kinds of power could be viewed via RCU as well as any other Modbus software as long as you read the right Modbus register number. Remote control is set as "manual" by default because the breaker could be close/open by mistake if it is in "Auto" mode to enable it.Ĥ. It is in Remote setup menu under "History, maintenance and setup" (Wrench sign). In the same way, remote control could be only modified locally too. Access permit and Access code could be changed here in Remote settings.ģ. setup menu under "History, maintenance and setup" (Wrench sign). Remote setting could be only modified locally via Micrologic P display. For example: value "32768" simply means that it is NOT applicable from register 560 to 571, 578 to581, or 585 to 586 in Micrologic 6.0PĢ. NOT all Modbus registers in use for Micrologic P. I attach a document where you can see my readings with the readings using the modscan and the readings using Micrologic_RCU.ġ.
Don`t know why if this software can read the micrologics's registers why the other ones not. * downloaded software from the schneider's webpage called Micrologic_RCU, this software permit us read parameters as currents, power factors (PF's), voltages and the different kinds of power.
In the user's guide, its says that "if you want to enable this option you need to call to your sales manager". * There's an option in the micrologic's menu that can't be changed and this is the next: "remote access = NO". More precisely, many registers before the direction 401000 (301000) also read the same. *When trying to read the registers farther of the direction 401000 (301000), returned values are only "32768". Those directions give us some information about baud rate, node, and other communications parameters.
*can read the registers from the directions 400000 (300000) until the directions 401000 (or 301000) using a software for PC (modscan and kepserver).